ZIPS-Vector, sandwich-panel
The thinnest composite structure for additional acoustic insulation of walls and ceilings.
The panel system for sound isolation of basic level ZIPS-Vector is an effective solution for the problem of additional sound isolation for the existing walls. It allows to solve the problems of sound isolation for everyday noise - speech, dogs barking, low intensity sound from radio/TV, etc. (the effective range of the system is from 125 Hz). Total thickness of the system together with finishing gypsum plasterboard layer equals 53 mm.


Application
The thinnest system for additional acoustic insulation of walls and ceiling slabs. Efficiently prevents low intensity domestic noises: talking, babies’ crying, TV-radio low-powered equipment. Operating range of the system is up to 125 Hz. It is used in construction and reconstruction of buildings to improve acoustic insulation of single-layer building constructions: gypsum, brick and concrete walls, partitions and armored concrete ceiling slabs. It is used for additional acoustic insulation of existing walls and ceiling slabs in living accommodations: flats and cottages.Composition
Panel sound insulating system ZIPS-Vector consists of sandwich-panels 40 mm thick and special finishing gypsum plasterboards AKU-line 12.5 mm thick. A sandwich-panel of Vector type is a combination of a GFB layer and glass staple fiber Shumostop. Every sandwich-panel consists of eight vibration-insulating fastening units by which it is being erected on walls or ceiling slabs.Distinctive characteristics:
- This design is unique, protected by RF patent No. 2140498.
- Fastening directly onto the bearing surface.
- Strong performances of additional acoustic insulation.
- Tongue-and-groove joint of sandwich-panels preventing appearance of gaps.
- Vibration insulating fastening units preventing transfer of sound waves from the bearing structure to the panel external surface.
Sandwich-panels ZIPS-Vector have been appropriately certified, have been classified to burning quality category G1 (low-flammable materials), their technical characteristics have been proved by laboratory tests. The material has been tested on many real objects and has showed good results.
Technology of Installation
Panel system ZIPS-Vector need to install in strict accordance with the instalation guide.Dimensions:
Dimensions of the sandwich panel (not including area of the protruding edges): 1200 x 600 mm.Thickness of the sandwich panel: 40 mm.
The total thickness of the system with the finishing single layer of 12,5 mm gypsum board: 53 mm.
Physical characteristics:
The weight of a single panel: 19,5 kg.The surface density of the system: 38 kg/m2.
Sound isolation for airborne noise:
Acoustic tests are conducted by the acoustic laboratory of NNSACU, Nizhniy Novgorod
Frequency, Hz | 100 | 125 | 160 | 200 | 250 | 315 | 400 | 500 |
---|---|---|---|---|---|---|---|---|
Silicate brick wall 120 mm (4.8 in)(Rw = 50 dB) | 41 | 42 | 39 | 39 | 44 | 41 | 42 | 42 |
Silicate brick wall 120 (4.8 in) mm + 40 mm (1.5 in) Zips Vector + 12,5 mm (0.5 in) gypsum plasterboard (Rw = 64 dB) | 36 | 40 | 44 | 51 | 59 | 59 | 63 | 66 |
Frequency, Hz | 630 | 800 | 1000 | 1250 | 1600 | 2000 | 2500 | 3150 |
Silicate brick wall 120 mm (4.8 in)(Rw = 50 dB) | 45 | 49 | 51 | 55 | 57 | 60 | 64 | 66 |
Silicate brick wall 120 mm (4.8 in) + 40 mm (1.5 in) Zips Vector + 12,5 mm (0.5 in) gypsum plasterboard (Rw = 64 dB) | 71 | 77 | 81 | 85 | 87 | 89 | 91 | 92 |
The additional sound isolation index for airborne noise for the ZIPS-Vector: ΔRw = 12 - 14 dB.
1. Surface preparation and installation ZIPS Panel system is mounted on existing walls, made of concrete blocks or bricks, monolithic reinforced concrete column and slabs. It is not recommended to mount a panel system for the construction of a thickness of less than 80 mm. Before the commencement of installation, the surface of walls and ceiling shall be leveled plaster mixture. Allowed irregularities and deviations of not more than 10 mm per linear meter of the surface. |
![]() |
2.Beginning instalation By the side walls and the ceiling, the ends of the sandwich panels should be placed through two layers of anti-vibration tape «Vibrostek-M». The ribbon is glued and fixed with sealant «Vibrosil». On the floor panel system is based through two layers of anti-vibration tape «Vibrostek-M». Strip «Vibrostek- M» also must be placed under the ends of gypsum and gypsum fiber boards, applied in the system. If the panel system is mounted on the ceiling, all adjacency to the side surfaces of the vibration-insulating tape “Vibrostek-M” in 2 layers. |
![]() |
3. Installation of sandwich panels Each sandwich panel has 8 vibroisolating joints for its fastening to the surface. The panels must be mounted strictly through vibroisolating joints. Installation of sandwich panels it is easier to engage from the bottom up, from left to right. In the first panel, the ridges are cut short and the long side, following panlay the first row only on the long side. The panel set as follows: the panel is applied to the wall, directly through vibroisolating joints drill the holes in the ceiling/wall depth of 60 mm.Insert the screws with whasher slightly attached to the plastic duwel (do not let the duwel to expand) into the hole. After the dowel is inserted in the drilled hole, hammer it until it stops and tighten placed under his head conical washer. |
![]() ATTENTION! The screw head has to be recessed into the surface of attachment joint no more than 1-2 mm! |
4. Trim panels Sandwich panels are joined together by means of a tongueand- groove connection, tongue-and-groove joints are additionally tightening the screws for gypsum-fiber Board 3x25mm, pitch of screws 150 mm. When the closure of a number of the panel can be pruned, wherein the trimmed portion goes to the next row. Cut out sandwich panels using a jigsaw, a layer of mineral wool is trimmed with a sharp knife. |
![]() |
5. Spacing of the conjunctions ZIPS Panel system is mounted on existing walls, made of concrete blocks or bricks, monolithic reinforced concrete column and slabs. It is not recommended to mount a panel system for the construction of a thickness of less than 80 mm. Before the commencement of installation, the surface of walls and ceiling shall be leveled plaster mixture. Allowed irregularities and deviations of not more than 10 mm per linear meter of the surface. |
![]() |
6. Fastening elements usage If the sandwich panel is completely placed on the surface of the wall – its installation is carried out only with the help of six vibroisolating joints (Central nodes are not used). If the wall panel is subject to pruning – using all the available mounts. When mounting the panels on the ceiling use in two central vibroisolating joints with metal anchor screws. Mount ZIPSCinema panel to the wall similarly. There are two types of anchor screws coming for installation of sandwich panels on the ceiling: standard (50 mm longer than the thickness of the sandwich panel) and shortened. Shortened anchor screws are used for installation on hollow core of floor slabs. |
![]() |
7. Finishing layer of AKU-line sheets The joints between sandwich panels should be treated with a sealant «Vibrosil» after installation. Lean finish layer of gypsum Board (12,5 mm thickness) to the resulting surface. The gypsum Boards should adjoin to adjacent surfaces through the double layer of vibration-insulating tape «Vibrostek-M» in accordance with point 2 of this manual. When installing gypsum boards use self-tapping screws 3,9 х 41 mm. Screws should not hit the vibrojoints of sandwich panels. The distance between screws has to be 200 mm vertically and 400 mm horizontally. |
![]() |
8. The final stage The excess of protruding tape «Vibrostek-M» is cut flush with the finish layer of gypsum Board. Joints filled acoustic silicone sealant «Vibrosil». To obtain a perfect weld, it is recommended to use masking tape, which is pasted on the surface, forming an angle. If necessary, the surface panel systems are additionally aligned for final finish. |
![]() |