English
+971581035366 / DubaiFree engineering consultation

Frame soundproofing ceiling on hangers Ultrakustik Connect (2 layers)

Overview

The structures of frameless soundproof linings are used in construction and renovation of buildings of any type and purpose for additional sound insulation of single-layer massive walls and ceilings. They have high values of weighted sound reduction index improvement of air noise and low level of radiated sctuctural noise.

Other constructions in this section

You can calculate the approximate estimate of sound insulation in your case. To do this, it is enough to enter the surface area that is supposed to be isolated. The estimate is calculated with a 5% margin, as well as taking into account rounding to whole packages. Please note that the estimate is approximate, since it does not take into account the individual characteristics of your premises.

Show estimation for
Just input your area. The estimate is recalculated automatically.

Specialized sound insulation materials:

Material
Quantity
Unit of measurement
AKU-Line, Gyproc gypsum board
2500 x 1200 x 12.5 mm board (3m2/board)
1 0.42
-
pc
Soundline-dB, GFB
sheet 1200х1200х16.5 mm
1 0.7
-
pc
Shumanet-ECO
1250 х 600 х 50 mm, in a package 4 pcs./3,0 m2
1 1
-
pc

Specialized accessories:

Material
Quantity
Unit of measurement
Vibrostack-M100
vibration damping spacer roll 30 m, width 100 mm thickness 4 mm (3 m2)
1 0.73
-
pc
Ultrakustik Connect
versatile vibroinsulating hang 150x30 mm
1 2.8
-
pc
Vibroseal
silicone neutral sealant 290 ml cartridge
1 0.4
-
pc

General construction materials:

Material
Quantity
Unit of measurement
Profile Gyproc-Standart PP 60/27
length 3 r.m.
1 1.4
-
pc
Profile Gyproc-Standart PPN 28/27
length 3 r.m.
1 0.24
-
pc
Extension PP 27х60
1 1
-
pc
Connector PP 27х60
two-level
1 3.1
-
pc
  • The frame is fixed to the ceiling with the help of ULTRAKUSTIK Connect or vibration insulating hangs. Rigid structural elements must adhere to all walls through an elastic spacer made of Vibrostack-M 100 Tape material in two layers. The sound-absorbing slab Shumanet- ECO is laid in the inner space of the frame in two layers.
  • After sound-absorbing slabs laying the frame is sheathed in one layer with SoundlinedB acoustic GFB triplex, and finish AKULine plasterboard plasterboard sheets are directly attached to them.
  • Soundline-dB and Gyproc Aku-line sheet facing materials are fixed with a stagger between joints. Upon completion of installation soundproofing framed cladding, the excess of protruding Vibrostack-M 100 Tape is cut off and the resulting joint is filled with Vibroseal.